{"id":39614,"date":"2020-08-07T12:32:48","date_gmt":"2020-08-07T10:32:48","guid":{"rendered":"https:\/\/mie-scintron.com\/service\/accessories\/ecg-trigger-monitor-cables\/"},"modified":"2020-08-07T12:46:17","modified_gmt":"2020-08-07T10:46:17","slug":"ecg-trigger-monitor-cables","status":"publish","type":"page","link":"https:\/\/mie-scintron.com\/de\/service\/accessories\/ecg-trigger-monitor-cables\/","title":{"rendered":"Cardiac Trigger Monitor"},"content":{"rendered":"
[vc_row][vc_column width=”1\/2″][vc_single_image image=”39504″ img_size=”full” onclick=”img_link_large”][\/vc_column][vc_column width=”1\/2″][vc_column_text]<\/p>\n
[\/vc_column_text][vc_column_text]<\/p>\n
Zur synchronen R-Zacken Triggerung bei verschiedensten Untersuchungen, wie zum Beispiel der Gated SPECT- und RNV-Technik.<\/p>\n
[\/vc_column_text][vc_column_text]<\/p>\n
4 Ableitungen mit 6 Pin AAMI Standardstecker, zu GND isoliert fu\u0308r Spannungen > 4 kV rms, 5,5 kV peak<\/p>\n
LC Display und Recorder<\/p>\n
Gefiltert 1,5 \u2013 40 Hz oder 3,0 \u2013 25 Hz<\/p>\n
Ungefiltert 0,67 \u2013 100 Hz EKG<\/p>\n
Ausgang ungefiltert 0,67 \u2013 100 Hz<\/p>\n
Durchfu\u0308hrung 10 Hz AC-Signal < 10 \u03bcA rms<\/p>\n
Messbereich 200 k\u03a9 \/ Ableitung<\/p>\n
Messgenauigkeit \u00b1 3 % \u00b1 1 k\u03a9<\/p>\n
Haut-Klebeelektrode<\/p>\n
Sensor: Silver \/ Silverchlorid<\/p>\n
Geltyp: Nassgel<\/p>\n
Anschluss: Druckknopf<\/p>\n
Verz\u00f6gerung Triggerausgang < 2 ms R-R<\/p>\n
Genauigkeit \u00b175 \u00b5s @ 1 mV Eingangssignal<\/p>\n
Einstellungen Impulsdauer 1 ms, 50 ms, 100 ms oder 150 ms<\/p>\n
Einstellungen Amplitude 0 V bis +5 V oder -10 V bis +10 V<\/p>\n
Ausgangsimpedanz < 100 \u03a9 *Eingangstestsignal fu\u0308r EKG-Ableitungen<\/p>\n
Bedingungen: \u03a9 Sinuswelle, 60 ms Impuls- dauer, 1 mV Amplitude, 1 Impuls \/ sek<\/p>\n
High Rate 15 \u2013 250 bpm (5 bpm Schritte)<\/p>\n
Low Rate 10 \u2013 245 bpm (5 bpm Schritte)[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"
[vc_row][vc_column width=”1\/2″][vc_single_image image=”39504″ img_size=”full” onclick=”img_link_large”][\/vc_column][vc_column width=”1\/2″][vc_column_text] Cardiac Trigger Monitor \u2013 IVY Model 7600 [\/vc_column_text][vc_column_text] Zur synchronen R-Zacken Triggerung bei verschiedensten…<\/p>\n","protected":false},"author":1,"featured_media":39505,"parent":39570,"menu_order":13,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"categories":[],"tags":[497,498],"acf":[],"_links":{"self":[{"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/pages\/39614"}],"collection":[{"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/comments?post=39614"}],"version-history":[{"count":0,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/pages\/39614\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/pages\/39570"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/media\/39505"}],"wp:attachment":[{"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/media?parent=39614"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/categories?post=39614"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mie-scintron.com\/de\/wp-json\/wp\/v2\/tags?post=39614"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}