{"id":52262,"date":"2020-07-13T12:01:10","date_gmt":"2020-07-13T10:01:10","guid":{"rendered":"https:\/\/dev.mie-scintron.com\/accessories\/ecg-trigger-monitor-cables\/"},"modified":"2025-09-10T15:56:24","modified_gmt":"2025-09-10T13:56:24","slug":"ecg-trigger-monitor-cables","status":"publish","type":"page","link":"https:\/\/mie-scintron.com\/en-US\/components\/ecg-trigger-monitor-cables\/","title":{"rendered":"ECG trigger monitor &#038; cables"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;52263&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221; css=&#8221;&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h2 style=\"text-align: left;\">Cardiac Trigger Monitor<\/h2>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<p class=\"p1\">ECG trigger for use in synchronized application in Nuclear and Molecular Imaging such as Gated-SPECT and MUGA studies.<\/p>\n<ul>\n<li>intuitive operation and reliable cardiac trigger<\/li>\n<li>user specific pulse amplitude options of 1, 50, 100 or 150 ms<\/li>\n<li>active Matrix TFT 6.5\u201c (16.5 cm) Color Touch Screen with a 640 x 480 Resolution<\/li>\n<\/ul>\n<h5>Technical Specifications:<\/h5>\n<ul>\n<li>Voltage Input: 100 -120 V~ \/ 200-230 V~<\/li>\n<li>Line Frequency: 50 \/ 60 Hz<\/li>\n<li>Max. Power Consumption: 45 VA<\/li>\n<\/ul>\n<h5>Dimensions:<\/h5>\n<ul>\n<li>Height: 7.49\u201c (19.02 cm)<\/li>\n<li>Width: 7.94\u201c (20.17 cm)<\/li>\n<li>Depth: 5.18\u201c (13.16 cm)<\/li>\n<li>Weight: 3.9 lbs (1.8 kg)<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<h5>Technical Specifications:<\/h5>\n<h6>Patient Cable<\/h6>\n<p>4 Lead cable with 6 PIN AAMI standard connector, isolated from ground related cir- cuits by &gt; 4 kV rms, 5.5 kV peak<\/p>\n<h6>Frequency Response<\/h6>\n<p>LCD Display and Recorder<\/p>\n<p>Filtered 1.5 to 40 Hz or 3.0 to 25 Hz<\/p>\n<p>Unfiltered 0.67 to 100 Hz<\/p>\n<p>ECG Output Unfiltered 0.67 to 100 Hz<\/p>\n<h6>Electrode Impedance Measurement<\/h6>\n<p>Technique 10 Hz AC-Signal &lt; 10 \u03bcA rms<\/p>\n<p>Range Range 200 k\u03a9 per lead<\/p>\n<p>Accuracy \u00b13 % \u00b11 k\u03a9<\/p>\n<h6>Recommended Electrode<\/h6>\n<p>10 % Chloride sponge type<\/p>\n<h6>Synchronized Output (Trigger)*<\/h6>\n<p>Output Trigger Delay &lt; 2 ms<\/p>\n<p>R to R Trigger Accuracy \u00b175 \u00b5s @ 1 mV input<\/p>\n<p>Pulse Width Options 1 ms, 50 ms, 100 ms or 150 ms<\/p>\n<p>Pulse Amplitude Options 0 V to +5 V or -10 V to +10 V<\/p>\n<p>Output Impedance &lt; 100 \u03a9<\/p>\n<p>*Test input signal at ECG leads Conditions: 1\/2 sine wave, 60 ms width, 1 mV amplitude, 1 pulse\/second<\/p>\n<h6>Alarms<\/h6>\n<p>High Rate 15 \u2013 250 bpm (5 bpm increments)<\/p>\n<p>Low Rate 10 \u2013 245 bpm (5 bpm increments)[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;51338&#8243; img_size=&#8221;full&#8221; add_caption=&#8221;yes&#8221; onclick=&#8221;link_image&#8221; css=&#8221;&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;51339&#8243; img_size=&#8221;full&#8221; add_caption=&#8221;yes&#8221; onclick=&#8221;link_image&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;52263&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221; css=&#8221;&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Cardiac Trigger Monitor [\/vc_column_text][vc_column_text] ECG trigger for use in synchronized application in Nuclear&#8230;<\/p>\n","protected":false},"author":1,"featured_media":52263,"parent":53239,"menu_order":13,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"categories":[],"tags":[653,661],"class_list":["post-52262","page","type-page","status-publish","has-post-thumbnail","tag-accessories-en-us","tag-patient-positioning-en-us"],"acf":[],"_links":{"self":[{"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/pages\/52262","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/comments?post=52262"}],"version-history":[{"count":9,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/pages\/52262\/revisions"}],"predecessor-version":[{"id":53318,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/pages\/52262\/revisions\/53318"}],"up":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/pages\/53239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/media\/52263"}],"wp:attachment":[{"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/media?parent=52262"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/categories?post=52262"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mie-scintron.com\/en-US\/wp-json\/wp\/v2\/tags?post=52262"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}